Power Supply Voltage | DC24V (-15%/+10%) |
---|---|
Operating Distances | Rated Operating Distance: 12mm Assured Switch ON Distance : 10mm Assured Switch OFF Distance : 15mm Hysteresis : 2mm Repeat Accuracy : <5% |
Safety Output Protection | Internal Fuse 2A |
Operating Temperature | -25 – +60°C |
Type Coding Level (ISO 14119) | 4 / Low |
MTTFd | >100 years |
Complied Standards | ISO 13849-1, ISO 14119, IEC 60204-1, IEC 61508-1, IEC 61508-2, IEC 62061, IEC 60947-5-3, UL 60947-1, UL 60947-5-2, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-5-2, CE, RoHS |
Models | SS2-P-310 | SS2-P-320 | SS2-P-330 |
---|---|---|---|
Safety Output | N.O. Contact x 1 N.C. Contact x 1 (AC48V 2A (AC General Use) / DC30V 2A (DC Resistive) / DC5V 10mA Min.) | ||
Auxiliary Output (x1) | N.C. x 1 (SSR Output) | N.C. x 1 (PNP Open Collector Output) | N.C. x 1 (NPN Open Collector Output) |
DC24V 200mA Max. | |||
Contact Configuration | |||
Operating Current | 60mA | 215mA | 60mA |
Safety Relay Unit | Can be used with safety relay unit receiving 1 N.O. + 1 N.C. input / Cannot be used with SM1-301 of Line Seiki | ||
Dimensions | Transmitter Unit : 92 x 25 x 17 mm Receiver Unit : 92 x 25 x 24.5 mm | Dimension | |
Weight | Transmitter Unit : 80g Receiver Unit (including cable) : 230g | ||
Protection Class | IP68 | ||
PL | PLd (Cat.3), SIL2: Stand-alone (1 safety switch) Performance level depends on evaluation of entire system: Combined with a relay unit (1 N.O. + 1 N.C.) |