Distributors ListContact Us
Copyrightc Line Seiki Co., Ltd. 2000- All rights reserved.
Home/Products & Services/Electronic Counters/E48 Series
Stock Only

Electronic Preset CountersE48 Series

  • 6 digits
  • LCD
  • Add/Subtract
  • External power supply
  • 48×48mm
  • With output
FeaturesCE marking
Compliant to RoHS
Easy to edit/program (Individual digit keys)
Blue STN LCD display with white backlight
Multi-functions: prescaling; key locking; setting decimal-point position; programing initial value at resetting

Models

ModelsDigitsPresetPower sourceInputOutputBody length
Discontinued
E48-101
61 Level presetAC100 – 240VContact / Open collector
Voltage input
(Selectable)
Relay output (1c)
AC250V 5A /
DC30V 5A MAX
100mm
Stock Only
E48-102
DC12 – 24V64mm
Stock Only
E48-201
2 Level presetAC100 – 240VRelay output (Main: 1c, Sub: 1a )
AC250V 5A /
DC30V 5A MAX
100mm
Discontinued
E48-301
1 Level preset + prewarn
Discontinued
E48-111
1 Level presetAC100 – 240VNPN Open Collector output
DC45V 100mA MAX
100mm
Discontinued
E48-112
DC12 – 24V64mm
Stock Only
E48-211
2 Level presetAC100 – 240V100mm
Discontinued
E48-311
1 Level preset + prewarn

* All mode key protecting function can be added. (example : E48-101K)

Specifications

ModelsE48-101/111E48-102/112E48-201/211E48-301/311
DisplayBlue STN LCD with white backlight ; Digit Size : 10mm x 5mm
No. of Digits6
No.of Digits Setting key6
Preset Level1121 Level preset + prewarn
Setting Range-99999 – +999999
Prewarn Feature0 – 999999
Input ModeContact / Open collector Voltage input (Selectable)
Input SignalOpen Collector (Sink current approx. 11mA ) L : 0 – 4V /
Voltage (Input impedance 7KΩ) L : 0 – 4V H : 6 – 30V (Available to duplex wire DC sensor.)
Maximum Count speed30Hz, 1kHz, 5kHz, 10kHz (selectable)
Count ModeAdd/Subtract (Add/Subtract individual input, 90° quadrature input)
Count Range-99999 – +999999
Prescale0.001 – 99.999 ( 0 setting is not available )
Decimal Point Position0.0, 0.00, 0.000, No decimal point
Write-99999 – +999999
ResetFront panel reset, Remote reset,Auto-reset
Remote Reset Time2msec or 20msec (selectable)
Reset ModeModes A, B,C,D, E, F,G can be selected.
Except for standard output,Mode A only is available for other output modes.
MemoryE²PROM (10 years, can be used 100,000 times)
Output DelayE48-□0□ : Relay output /30Hz : 17ms MAX. / 1kHz,5kHz,10kHz :12ms MAX.
E48-□1□ : Open collector output /30Hz : 7ms MAX. / 1kHz,5kHz,10kHz : 2ms MAX.
Output Mode1 Level Preset: Standard, Equal, Lower Limit,Upper Limit
2 Level Preset: Standard, Equal,Upper-Lower Limit,Upper-Upper Limit
1 Level Preset + Prewarn: Standard, Equal
Output TimeStandard output : one shot ( 10 – 9990ms ) or HOLD or HOLD 1 or HOLD 2 / Equal,Upper, Lower output : Latched only when requirements are full
Key LockKey operation can be disabled at 4 protection levels (L1, L2, L3, L4) by selecting in Program Mode and shorting key lock terminals.
Error DisplayIn 90° quadrature mode, error message will be displayed on the LCD if the count range is exceeded (overflow error : underflow error : )
Power SupplyAC100 – 240V
-15%, +10%
DC12 – 24V
-15%, +10%
AC100 – 240V
-15%, +10%
DC12 – 24V
-15%, +10%
Sensor Power SourceDC12V 100mADC12V 100mADC12V 100mA
Power ConsumptionApprox. 7VA for AC240VApprox. 2.5W for DC24VApprox. 7VA for AC240VApprox. 7VA for AC240V
Ambient Temp. : Operating-10 – +50°C (non-freezing)
Ambient Humid. : Operating45 – 85%RH (non-condensing)
Altitude2,000m max.
Installation EnvironmentOver-voltage category II , Pollution degree 2 (IEC61010-1)
Front PanelIP54 (panel surface)
WeightApprox. 160gApprox. 120gApprox. 160gApprox. 160g
ComplianceCE, RoHS, UL

Feel free to contact us