| Model | F90-101 | F90-201 |
|---|---|---|
| Type | Monitor Type | Upper / Lower Limit Preset Type |
| Display | Red LED 14.22 x 7.8mm | Measuring Display : Red LED 10.5 x 5.5mm Preset Display : Green LED 8.0 x 4.0 mm |
| Number of Digits | 6 | |
| Display Range | 0.0001 – 999999 | |
| Decimal Point Position | 4th decimal point position max. | |
| Scale Range | 0.11 – 20KHz (1pulse / revolution : 6.6667 – 120000rpm) | |
| Preset Level | – | Upper / Lower Limit |
| Measuring Method | 1/TAU standard sampling : X’tal 2MHz ±50ppm | |
| Measuring Accuracy | ±0.008% reading ±1 digit (multiplier = 1.0000, divider = 1, -5 – +50°C ) | |
| Sampling Time | 0.5 – 10 seconds (sampling time is changed automatically by pulse interval) | |
| Up-date Time | Every sampling or 1 – 99seconds (maximum) | |
| Input Signal | Contact inpu t: sink current 2mA Open collector input sink current : 2mA L : 0 – 1.9V Voltage input : input impedance 3KΩ L : 0 – 1.9V H : 3.5 – 30V (P-P3.5V min.) Magnetic sensor input : input impedance 3KΩ L : -0.6 – -17V H : 0.6 – 17V | |
| Input Frequency | Contact input 0.11 – 25Hz minimum pulse width 20msec Open collector or Voltage input 0.11H – 20KHz minimum pulse width 25msec Magnetic sensor inpu 0.11 – 20KHz minimum pulse width 25msec (L : -0.6Vmax. / H : 0.6Vmin) | |
| Prescale | Multiplier : 0.0001 – 100 Divider : 1/1 – 1/9999 (can be used at the same time) | |
| Overflow | At every sampling, when the measured data is over 6 digits, “—–” is displayed | |
| Memory | Prescale value, upper/lower limit value and up date time are retained for 10 yrs. by E²PROM (rewrite 10000 times) | |
| Keylock | Prescale value, upper/lower limit value (exclude monitor type) and up date time are inhibited to be changed. Contact input, Open collector input (sink current 7mA L : 2Vmax) | |
| Output Inhibition | – | Upper / Lower Limit output inhibition Contact input, Open Collector input (sink current 7mA L : 2Vmax) |
| Upper / Lower Output | – | Type 1C relay contact (AC250V/0.5A or DC30V/2A) |
| Sensor Supply Power Source | 12VDC ±10% 100mA max. (Analog output is 50mA maximum) | |
| Power Supply | 100 – 240VAC -15% +10% (85 – 264VAC) 50/60Hz | |
| Power Consumption | Approximately 6VA | |
| Ambient Temp. : Operating | -5 – +50°C (Non-freezing) | |
| Ambient Humid. : Operating | 45 – 85%RH (Non-condensing) | |
| Weight | Approx. 280g | |
| Compliance | – | |
Stock Only
Panel Type TachometerF90 Series
| Features | Digital Tachometer of DIN 96 x 48 mm panel size (Panel cut size 92 x 45 mm) Measuring method: 1/TAU standard sampling : X'tal 2MHz ±50ppm Pre-scaling function Ingress Protection (front panel): IP54 |
|---|
Models
| Models | Type | Output |
| Stock Only F90-101 | Monitor Type | – |
| Discontinued | Analog | |
| Stock Only F90-201 | Upper / Lower Limit Preset Type | – |
| Discontinued | Analog |