Models | G48-305N / G48-305CN / G48-305TN | G48-315N / G48-315TN | G48-306N / G48-306CN |
---|---|---|---|
Display | LCD display with backlight ; Digit Size : 10mm x 5mm | ||
No. of Digits | 6 | ||
No.of Digits Setting key | 6 | ||
Preset Level | 1 Level | 2 Levels / 1 level preset + prewarn (selectable) | 1 Level |
Setting Range | -99999 – +999999 | ||
Prewarn Feature | – | 0 – 999999 | – |
Input Mode | Contact / Open collector Voltage input (Selectable) | ||
Input Signal | Open Collector (Sink current 10mA,DC power model: power supply volt / 1.2KΩ) L : 0 – 4V Voltage (Input impedance 7KΩ) L : 0 – 4V H: 6 – 30V (Available to use 2-wire DC sensor) | ||
Maximum Count speed | 30Hz, 1kHz, 5kHz (selectable) | ||
Count Mode | Add, Subtract, Add/Subtract (Add/Subtract individual input, Add/Subtract direction, 90° quadrature input) | ||
Count Range | -99999 – +999999 | ||
Input Inhibition | Incoming pulses can be inhibited by Input B only with Add mode and Subtract mode. | ||
Prescale | Multiplying : 0.001 – 99.999 / Dividing : 1 – 999 (0 setting is not available / Multiplier and divider combinable) | ||
Decimal Point Position | 0.0, 0.00, 0.000, or No decimal point | ||
Write | -99999 – +999999 | ||
Reset | Front panel reset, Remote reset, Auto-reset | ||
Remote Reset Time | 2msec or 20msec (selectable) | ||
Reset Mode | Any Operation Mode(A,B,C,D,E,F or G) can be selected for Standard Output mode. For other modes, only Mode A is available. | ||
Memory | E²PROM (10 years, Overwrites : 100,000 times) | ||
Output | G48-305N Relay output (1a) : G48-315N load of AC250V 5A / DC30V 5A MAX. G48-305CN Relay output (1c) : G48-305TN Non-contact output NPN Open-collector : | ||
Output Delay | G48-305N / G48-305CN G48-305TN / G48-315TN : 30Hz : 6ms MAX. ; 1kHz, 5kHz : 3ms MAX. | ||
Type of Output | 1 Level Preset : Standard, Equal, Lower Limit, Upper Limit 2 Level Preset : Standard, Equal, Upper-Lower Limit, Upper-Upper Limit 1 Level Preset + Prewarn : Standard, Equal | ||
Output Time | output : One shot (10 – 9990ms / 10ms step) or HOLD (or HOLD 1 or HOLD 2 in G48-315N model and G48-315TN model) (selectable) For other output modes : HOLD while the count value meets the conditions | ||
Key Lock | Key operation can be disabled at 4 protection levels (L1, L2, L3, L4) by selecting in Program Mode and shorting key lock terminals. | ||
Error Display | In Add/Subtract individual input, Add/Subtract direction,90° quadrature mode, error message will be displayed on the LCD if the count range is exceeded (overflow error : underflow error :) | ||
Power Supply | AC100 – 240V -15%, +10% | DC12 – 24V -15%, +10% | |
Sensor Power Source | DC12V 100mA | – | |
Power Consumption | Approx. 7VA for AC240V | Approx. 1.2W for DC24V | |
Ambient Temp. : Operating | -10 – +50°C (non-freezing) | ||
Ambient Humid. : Operating | 45 – 85%RH (non-condensing) | ||
Front Panel | IP54 (panel surface) | ||
Weight | Approx. 170g | Approx. 110g | |
Compliance | CE, RoHS, UL |
NEW
Electronic Preset CountersG48-N Series
- 6 digits
- LCD
- Add/Subtract
- External power supply
- 48×48mm
- With output
Features | Easy to edit/program (Individual digit keys) Backlight LCD Preset Counter Multi-functions: prescaling; key locking; setting decimal-point position; programing initial value at resetting Prescaling consists of both multiplying and dividing |
---|
Models
Models | Digits | Preset | Power source | Input | Output | Body length | Remarks |
G48-305N | 6 | 1 Level preset | AC100 – 240V | Contact / Open collector / Voltage input | Relay output (1a) | 100mm | |
G48-305CN | Relay output (1c) | ||||||
G48-305TN | NPN Open Collector output | Production on order | |||||
G48-306N | DC12 – 24V | Relay output (1a) | 64mm | ||||
G48-306CN | Relay output (1c) | ||||||
G48-315N | 2 level preset / 1 level preset + prewarn (Selectable) | AC100 – 240V | Relay output (1a) | 100mm | |||
G48-315TN | NPN Open Collector output | Production on order |