Function | Pulse Filter |
---|---|
Display | 4-Digit, 7-Segment LCD / Digit Size:7mm |
Setting Range | 00:01 – 99:59(mm:ss) |
Input | Pulse Input(Input) Key Protect(K/P) |
Input Type | Non-contact / Reed Input: Open Collector Input L<2V(Sink Current approx. 1mA) |
Input Frequency | 10Hz(Pulse Input) |
Output | Non-contact Output:NPN Open Collector(DC30V 100mA max.) Relay Output:1c Contact(AC/DC30V 0.5A max.)(M13-210 only) |
Output Type | One-shot(100ms) |
Output Delay | 25msec |
Key Protect | via Key Protect Input |
Memory | E²PROM(10 years Data Retention; 10,000 Re-write Cycles) |
Power Supply | DC12 – 24V(-15% / +10%) |
Power Consumption | approx. 0.4W(at DC24V) |
Ambient Temp. : Operating | -10 – +50°C(non-freezing) |
Ambient Humid. : Operating | 45 – 85%RH(non-condensing) |
Ambient Temp. : Storage | -20 – +60°C(non-freezing) |
Noise Immunity | Square-wave Noise from Noise Simulator Power Supply Terminal: ±600V / Input Terminal: ±500V |
Vibration Resistance | Malfunction: 10 – 55Hz peak amplitude 0.15mm 3-directiona 10 minutes Endurance: 10 – 55Hz peak amplitude 0.375mm 3-directional 2 hours |
Dimensions | 90 (L) x 52 (W) x 57 (H) mm |
Weight | Approx. 110g |
Compliance | CE, RoHS |
Pulse ManipulatorsM13-211(Pulse filter)
Features | Pulse quantity changer Receives pulses for a predetermined amount of time, and makes an output as a one-shot pulse Setting time range: 0.1 seconds to 999.9 seconds DIN Rail mountable |
---|