Models | MD-040 | MD-040M |
---|---|---|
Display | Red LED, 14.22 x 8.13mm (Zero Suppress) | |
Input Method / Signal | Contact Input : Relay, Microswitch Non-Contact Input : L : 0 – 1V ; H : +4.5 – 27 | |
Count Mode | Additive only | |
Maximum Count Speed | Contact Input : 20 Hz max. / Non-Contact Input : 1000 Hz max. | |
Pulse Width | Contact Input : 25 msec min. / Non-Contact Input : 0.5 msec min. | |
Make (Duty) | 1 : 1 | |
Reset | Front reset (push button) Remote reset (100msec min.) Electric reset (1sec min.) | Front reset (push button) Remote reset (100msec min.) |
Memory | None | E²2PROM (10 years. retention, 10,000 times) |
Power Source for Sensor | DC12V 30mA maximum | |
Input Impedance | 5kΩ | |
Power Source | AC100/110V or AC200/220V ±10%, 50/60 Hz | |
Power Consumption | Approximately 2.5VA | |
Ambient Temp. : Operating | -5 – +40°C (non-freezing) | 0 – 40°C (non-freezing) |
Ambient Humid. : Operating | 45 – 85%RH (non-condensing) | |
Hi-pot Test | AC1500V (1 minute) | |
Dielectric Test | 20MΩ min. (DC500V megger) | |
Connection | M3 Terminal Screw | |
Compliance | – |
Electronic Total CountersMD Series
- 4 digits
- LED display
- Add
- External power supply
- 72×72mm
Features | Totalizer of DIN 72 x 72 mm panel size (Panel cut size 68 x 68 mm) Red LED display, 14.22 mm figure height Zero suppress, large display Pulse Counter |
---|
Models
Models | No. of Digits | Memory | Weight |
MD-040 | 4 | – | 500 grams |
MD-040M | O | 510 grams |