Distributors ListContact Us
Copyrightc Line Seiki Co., Ltd. 2000- All rights reserved.
Home/Products & Services/Length Counters & Sensors/CR Series
New Model Arrived

Length SensorCR Series

  • 1m/10cm/1cm
  • Add only and Add/Subtract
  • Voltage
  • Open collector
FeaturesFor simple length measurement of textiles, papers, films, etc. in conjunction with electronic counters, and PLC
CR-AC/CR-A (One-Output) Type: increment only, no matter which direction its wheels rotate
CR-RC/CR-R (Two-Output) Type: increment for positive rotation, decrement for negative rotation of the wheels (90°quadrature output)
Resolution 1 m/y, 0.1 m/y, 0.01 m/y, depending on model number
A pair of rubber pulleys(wheels) are included
Urethane pulleys(wheels) are available as an option per application

Models

ModelSensorUnitMaximum
Speed
WeightRotation
Torque
Proper
Counter
CR-3:1ACPhotoelectronic Sensor,
1 Non-contact Output
( Open Collector Output )
1m (yard)700meter/min (yard/min)605g20mN.mElectronic
Counter
CR-3:10AC0.1m (yard)700meter/min (yard/min)
CR-3:100AC0.01m (yard)250meter/min (yard/min)
CR-3:1RCPhotoelectronic Sensor,
2 Non-contact Outputs
( Open Collector Output,
90° Quadrature Output )
1m (yard)700meter/min (yard/min)610gBi-directional
Electronic
Counter
CR-3:10RC0.1m (yard)500meter/min (yard/min)
CR-3:100RC0.01m (yard)250meter/min (yard/min)
CR-3:1APhotoelectronic Sensor,
1 Non-contact Output
( Voltage Output )
1m (yard)700meter/min (yard/min)605gElectronic
Counter
CR-3:10A0.1m (yard)700meter/min (yard/min)
CR-3:100A0.01m (yard)250meter/min (yard/min)
CR-3:1RPhotoelectronic Sensor,
2 Non-contact Outputs
( Voltage Output,
90° Quadrature Output )
1m (yard)700meter/min (yard/min)610gBi-directional
Electronic
Counter
CR-3:10R0.1m (yard)500meter/min (yard/min)
CR-3:100R0.01m (yard)250meter/min (yard/min)

2 pieces of measuring wheel for meter are equipped as standard accessories.

Alternatively, 2 pieces of measuring wheel for yard are available.
Please order type of measuring wheel.
“-YP” should be added to the model number. (Ex.) CR-3:10AC-YP

Specifications

ModelOutputPower
source
Current
consumption
Output
voltage
Output
impedance
Maximum
load current
Cable Type
CR-3:1AC,
CR-3:10AC,
CR-3:100AC
1 OutputDC5 – 24V
(±10%)
35mA100mA2-meters,
Shielded Cable
CR-3:1RC,
CR-3:10RC,
CR-3:100RC
2 Outputs
(90°Quadrature)
44mA
CR-3:1A,
CR-3:10A,
CR-3:100A
1 Output45mAH: Power Supply
Voltage -1V (min.)
55mA L: 0.5V (max.)
3.9kΩ
CR-3:1R,
CR-3:10R,
CR-3:100R
2 Outputs
(90°Quadrature)
55mA

 

Ambient Temperature: Operating-5 – +40°C
(Non-freezing)
Ambient Humid. : Operating35 – 85%
(Non-Condensing)
Structure ProtectionIP41 (IEC 60529)ComplianceCE, RoHS

Download

CASESApplication examples of this solution.

Feel free to contact us

Please contact us
for further information.