G86 Series
Product Type: Large Display
The G86 Series is an X-large display unit only LED digit size of 100 x 60mm. Several units of G85 or G86 can be stacked together in any configuration to create a multi-display unit. The multi-display unit can serve as a information board in a production floor or as a queing display board in large offices. Multiple case sizes are available from 589 x 180mm upto 680 x 180mm. Single or Double sided display is possible. The G86 Series is available in 4 - 6 digits and it accepts BCD input signal from smaller counters, panel meters or process controllers. Power source is AC100 - 240V. The G86 Series has a very sturdy and heavy duty casing which can be hanged, base or wall mounted.
Discontinued in 2014
Download:
Models | Digits | Memory | Features | Caase Size | Weight (KG.) | |
G85-101 | 4 | Single Side | BCD Input Display | S | 6.7 | |
G85-102 | 5 | |||||
G85-103 | 6 | L | 7.5 | |||
G85-104 | 4 | Double Side | S | 7.1 | ||
G85-201 | 5 | |||||
G85-202 | 6 | L | 8.0 |
Display | G86-105 | G86-115 | G86-205 | G86-215 | G86-305 | G86-315 |
Display | Red LED 101.6(H) x 60.0(W)mm | |||||
No.of Digits | 4 | 5 | 6 | |||
Power | AC100 - 240V -15% / 10% 50/60Hz | |||||
Input | Open Collector Transistor (L : 2Vmax H : 4 - 30V Sink Current 7mA)or Contact Input (digital switch) Parallel BCD ( Positive Logic / Negative Logic) |
|||||
Connection | Input : Terminal Screw Power : Terminal Screw Free Write : Amphenol Connector | |||||
Decimal Point | 0.0/0.00/0.00 | |||||
Display Range | 0 - 9999 | 0 - 99999 | 0 - 999999 | |||
Consumption | 9VA | 18VA | 10VA | 20VA | 11VA | 22VA |
Operating Temperature | -10 - +50°C (non-freezing) | |||||
Operating Humidity | 45 - 85%RH (non-condensing) | |||||
Hi-Pot Test | AC1500V 1minute | |||||
Dielectric Test | 100MΩ min. (DC 500V megger) | |||||
Noise Immunity | Pulse Wave Noise from Noise Simulator ±2.0KV (Power Terminals)±500V (Input Terminals) |
|||||
Casing | Coated Metal | |||||
Case Coating | N1.0(Black) Lasertone |
CAUTION!
Make sure to wait at least 1 minute after disconnecting the power of the unit before
touching or making changes to the Terminal Jumper positions.
Make sure that mounting fixtures are installed properly and screws are tightened.
When using Multi Level units, make sure that levels are connected properly and in order.
After completion of settings, make sure that door panels are properly closed and screwed
-
Production Monitoring
Getting the right information at the right time will streamline your production and will result to higher productivity.

- Electronic Counters
- Electromagnetic Counters
- Mechanical Counters
- Length Measuring Counters
- Limit Switch
- Shut Height Counter
-
Tally Counters
- DK-5005A
- DK-5005B
- DK-5005C
- DK-5005D
- DK-5005E
- DK-5000 Mieruzzo Basic Software for Win 7/8/8.1/10
- DK-5000 Mieruzzo Easy Tag Software for Win 7/8/8.1/10
- DK-5010A
- DK-5010B
- DK-5010C
- DK-5010D
- DK-5010E
- DK-5030A
- DK-5030B
- DK-5030C
- DK-5030D
- DK-5030E
- M16-600
- M16-601
- M16-602
- M16-301
- M16-302
- M16-303
- WLAN DK-5000 Mieruzzo Basic Software for Win 7/8/8.1/10
- Wireless DK-5000 Mieruzzo Basic Software for Win 7/8/8.1/10
- M13-215
- M13-206 / M13-207
- DK-100 Series
- DK-2300
- H-102P Series
- H-102 Series
- Timers
- Measuring Instruments
- Tachometers
- Rotary Encoders
- Length Sensors
-
Discontinued models
- Discontinued Model list
- CT Series
- DK-4500WB
- DK-4500 Communication SOFTWARE for Win Xp/Vista/7
- Data Logger Software DL2005
- DSP Series
- EA-1000
- EC-2000
- EH-1000
- EL-1000
- EM-1000
- EP-15 Series
- ER-1000
- ET-1000
- EW-1000
- G10 Series
- G11 Series
- G20 Series
- G21 Series
- G36 Series
- G60 Series
- G62 Series
- G80 Series
- G82 Series
- G85 Series
- G86 Series
- HT-7000
- LB Series
- LX-100
- MCH Series
- MCP-35
- MDR Series (Preset)
- MDR Series (Preset-BCD)
- MDR Series (Totalizer-BCD)
- RCP Series
- SL-24A(II)
- SP Series (Mechanical Counter)
- SP Series (Length Measuring Counter)
- SRP / RLP / RLS Series
- TC-250
- TC-330WP
- TC-400
- TC-950
- TC-2200
- TH-3000